What each Roland firmware version fixed, machine by machine
Reviewed: 22 October 2026
Booth briefing. Read the system version off the machine, find it below, and you know which documented fixes it carries and which it does not yet. Every entry comes from Roland's published version history: 57 documented fixes across 25 machines, 44 of which can interrupt a set already in progress.
On a machine you carry. On a house deck the version is somebody else's decision. A Roland in your bag is yours, so every fault below is one you can avoid by updating, and none of it needs a venue's permission.
Finding the version on the machine
Nothing on a TR panel displays the system version while it is playing. It lives in the utility or system menu, and on most of these machines it is shown for a moment on the startup screen. Check it at home, where you can do something about it, rather than at soundcheck where you cannot.
MX-1
Clear at 1.05 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.05 | Routing | When restoring parameters, Scene information was not restored correctly. |
| 1.03 | Audio mid-set | Input through the DIGITAL IN connector became monaural. |
| 1.02 | Browse | A factory reset might fail to be performed correctly. |
Roland's specification page for the MX-1 says the USB HOST ports are "for only TB-3/VT-3/TR-8/SYSTEM-1". Roland's firmware history says 1.03 added seven non-AIRA machines (JD-XA, JD-Xi, JUNO-Gi, JUPITER-50, JUPITER-80, FA-06, FA-08), 1.04 added the JUNO-DS and the XPS-30, and 1.05 added the SYSTEM-8: fourteen machines in all against the four on the specification page. Which machines the ports accept depends on the firmware version. 1.04 also added an Ableton mode with clip and scene playback, track solo, arm and mute, and AUX send. One more setting changed quietly at 1.03: after a factory reset the MIDI Clock Master default went from Auto to Int, so a reset machine stops following an external clock until that is put back.
DJ-808
No known defect for the DJ-808 across three releases. The only bug-fix text anywhere in its history is the generic "Minor bugs have been fixed" at 1.06 of November 2016. The capability floor is 1.10 of January 2018: a nudge function and a tap tempo for the TR-S, a Backspin Length setting, new Channel FX and an Input AUX mode, plus new TR-S drum sounds and effects and a wider reverb range on the mic effects. Roland confirmed Serato DJ Pro compatibility for this unit in March 2018, at that version. 1.05 of November 2016 added adjustable performance-pad sensitivity. The DJ-202 and the DJ-505 each received 1.11 in July 2019, fixing the TR-S failing against Serato DJ Pro 2.1.1 or later. This unit's published history stops at 1.10 in January 2018 and contains no equivalent entry. That is what Roland have published, and it does not show whether the DJ-808 has the same fault.
DJ-707M
Four releases, and none is a fix to chase: the only bug-fix text in its history is the generic "Minor bugs have been fixed" at 1.02. The history also carries changes that alter how the unit behaves in a room. 1.02 of August 2019 added Channel Effects and Vocal Effects and the ability to back up and restore scenes. 1.05 of March 2025 changed the default Auto Off time to 20 minutes, so an updated unit switches itself off during a long break unless Auto Off is turned off. 1.03 of February 2020 adjusted the initial value of MIC GAIN, which matters on a unit bought for microphone work. 1.04 of February 2022 changed only the version number, for management reasons.
DJ-505
Clear at 1.11 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.11 | Playback mid-set | The TR-S function fails to work correctly when used with Serato DJ Pro 2.1.1 or later. |
One named fault, shared with the DJ-202 and fixed in the same month at the same version number. More important, and not a fault: at 1.13 of March 2025 Roland changed the default Auto Off time to 20 minutes, so an updated unit switches itself off during a long break unless Auto Off is turned off in the system settings. 1.14 of November 2025 says only that minor bugs were fixed, with no symptom named, so it is not listed. 1.10 of January 2018 is the capability release: Step Loop and kit select for the TR-S, pad sensitivity, Backspin Length, and confirmed Serato DJ Pro compatibility from March 2018.
DJ-202
Clear at 1.11 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.11 | Playback mid-set | The TR-S function fails to work correctly when used with Serato DJ Pro 2.1.1 or later. |
| 1.03 | Playback mid-set | VINYL for DECK 3 and 4 could not be turned off from the software. |
Two named faults in eight years, and both are about the software reading the unit wrongly, not the unit failing. The release that changes what this controller can do is 1.10 of January 2018: Backspin Length, jog-dial top-surface sensitivity, TR-606 and TR-707 sounds, the TR-S kit count raised from 8 to 12, and the BPM range widened from 40-300 to 5-500. Serato DJ Lite compatibility was confirmed in March 2018. 1.04 says only "Minor bugs have been fixed" and names no symptom, so it is not listed. 1.12, 1.13 and 1.14 are version-number changes Roland attributes to management circumstances.
TR-1000
Clear at 1.15 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.15 | Audio mid-set | Sound would not be heard under certain conditions. Roland does not say which conditions. |
| 1.14 | Routing mid-set | CLK OUT was not synchronised with the sequencer, so anything clocked from this machine drifted from what you were hearing. |
| 1.14 | MIDI mid-set | MIDI Note-On messages were delayed. |
| 1.14 | MIDI mid-set | MIDI notes were not output when using SLICE. |
| 1.14 | MIDI mid-set | MIDI Note-Off messages were not output during INST PLAY, which leaves notes hanging on external gear. |
| 1.13 | FX mid-set | The MASTER FX SCATTER effect behaved incorrectly. |
| 1.13 | Display | CALIB could not be exited. |
| 1.11 | Playback mid-set | A fault during pattern chain, and a separate fault in Song Mode. |
The TR-1000 reached the market in October 2025 and all four of these releases fall inside its first four months, which is normal for a first year. An un-updated unit carries documented faults. The 1.14 group matters in a hybrid rig: delayed Note-On, missing Note-Off and an unsynchronised CLK OUT only show up when the TR-1000 is driving something else, and they are hard to attribute because they look like the other machine misbehaving. Releases from 1.16 onward are version-number changes Roland attributes to management circumstances; 1.20 of May 2026 is a feature release. There is no 1.12. Ver. 1.50, October 2026, is a large free feature release, not a fault fix: note sequencing (a step-entry mode for notes), a keyboard-play mode across the x0x triggers, 50 FM instruments carried over from the TR-8S, four new MFX effects, and a "keep EFX and EXT in" option that holds active effects and external inputs running across a kit or pattern change mid-set.
TR-8S
Clear at 2.51 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 2.51 | Performance mid-set | The unit may freeze on certain operations. Roland published the fix as a release of its own. |
| 2.03 | Playback mid-set | Switching VARIATION during playback could sound a different VARIATION than the one selected. |
| 2.01 | MIDI mid-set | MIDI could lose sync when the pattern was changed. |
| 1.13 | Sound | Importing a user sample could produce a silent sample. |
| 1.10 | Browse | Importing a pattern together with a kit could error, or import a different pattern. |
| 1.05 | Sound | After an OPTIMIZE of the user sample area, user samples could fail to play correctly. |
| 1.04 | Performance mid-set | Tap Tempo did not work at all. |
| 1.03 | MIDI mid-set | Under an external clock, effects failed to synchronise correctly to the tempo. |
| 1.02 | Playback mid-set | While editing a fill-in, a different variation could play. |
Nine documented faults, six of them able to interrupt a set in progress. Roland also made large feature additions in firmware, which are not listed as faults here: an FM tone generator and new INST FX at 2.00, FM MODEL INST and probability functions at 2.50, CR-78 tones at 3.00. After updating to 2.00 the preset kits and patterns it adds do not appear until a factory reset is performed, which looks like a failed update.
TR-8
Four releases, and none is a fix to chase. The only bug-fix text anywhere in its history is "Minor bugs have been fixed" at 1.60. There is still something to check: 1.50 of August 2017 expanded USB audio to 44.1, 48 and 96 kHz, and Roland note that 44.1 and 48 kHz also need driver version 1.5 or later, so updating one and not the other leaves rates the machine offers and the computer refuses. 1.60 added STEP LOOP, and 1.61 of January 2019 added Serato DJ Pro 2.1.1 synchronisation, live from February 2019. The TR-8 has a version floor, but it is a capability floor, not a defect floor.
TR-6S
Clear at 1.51 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.51 | Performance mid-set | The unit may freeze on certain operations. |
| 1.02 | Playback mid-set | Switching VARIATION during playback could sound a different VARIATION than the one selected. |
| 1.01 | MIDI mid-set | MIDI could lose sync when the pattern was changed. |
| 1.01 | Audio mid-set | Noise contamination when connecting to AIRA Link. |
The TR-6S and TR-8S share a firmware lineage, and the first three faults above are the same faults fixed in the same months under different version numbers: the freeze at TR-6S 1.51 and TR-8S 2.51, both October 2022; the VARIATION fault at 1.02 and 2.03, both September 2021; the MIDI sync fault at 1.01 and 2.01, both January 2021. The AIRA Link noise is the TR-6S on its own. Feature releases are not listed as faults: 1.03 let EXT IN arrive over USB audio, 1.50 added the FM MODEL tones and the probability functions, and 2.00 added the CR-78 tones.
TR-09
Two releases, and neither is a fix to chase. 1.06 of January 2019 is the release that makes this machine usable in a hybrid rig: it added USB and MIDI as MIDI clock sources, made soft thru switchable, and added Serato DJ Pro 2.1.1 support, live from February 2019. Below it the machine will not take a clock over USB. 1.04 of November 2016 added preset patterns, a MUTE function and a PAN setting, and the patterns do not appear until a factory reset is performed after updating, which looks like a failed update.
TR-08
Clear at 1.03 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.03 | Playback mid-set | Incorrect behaviour in MANUAL PLAY mode with BASIC-VARIATION set to AB and AUTO FILL IN set to MANUAL. |
One documented fault in the machine’s history. The release that makes a TR-08 useful in a booth is 1.07 of January 2019, which is an addition, not a fix: it added USB and MIDI as MIDI clock sources, made soft thru switchable, and added Serato DJ Pro support, live from February 2019 with Serato DJ Pro 2.1.1 or later. Below 1.07 the two reasons to carry this machine to a gig do not work. 1.06 and 1.08 are version-number changes with specifications unaffected.
TR-06
Roland publishes exactly one release for the TR-06, version 1.02 of November 2021, and describes it as a version-number change made for management reasons with product specifications unaffected. Roland has published no defect and no added feature for the TR-06. There is nothing to check and nothing to update.
T-8
Roland has published one firmware release for the T-8, 1.02 of May 2022, and its notes carry two kinds of change. The addition: the MIDI channel used to send and receive Program Change messages for pattern switching can now be set, where before it could not. The other is "Minor bugs have been fixed," the same generic text the DJ-808's 1.06 carries, so it is not listed as a fault. The T-8 has no CV/GATE, no trigger outputs and no 5-pin MIDI: SYNC, MIX and MIDI each run on their own stereo mini-phone jack, and reaching standard 5-pin MIDI gear needs Roland's optional BOSS TRS-MIDI cable, not the Boutique line's trigger or CV sockets.
SH-4d
Clear at 2.00 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 2.00 | Sound mid-set | The tone could change unintentionally when operating the PATTERN or MIXER screen. |
| 2.00 | Performance mid-set | Sequencer operation could be delayed when using the DRAWING model. |
| 2.00 | Playback mid-set | Shuffle behaved wrongly when the number of steps was odd. |
One release in this machine's history carries faults, and all three show up while you are playing, not while you are loading. It is also the largest Roland update in this matrix: 2.00 of May 2025 carries these three fixes plus roughly a dozen additions. Two of those additions change what the machine can do. STEP and HARMONIC were added to the oscillator models and a Pattern Chain function arrived, and "The USB driver now supports Generic", meaning the machine became class compliant: below 2.00 the computer needs their driver, at 2.00 and above it does not. 1.03 of April 2023 was a version-number change made for production reasons with specifications unaffected, and 1.02 of February 2023 added Voice Reserve and stabilised operation during pattern playback without naming a symptom, so it is not listed. Updating uses mass-storage mode and the supplied Type-C to Type-A cable; Roland state that charging cables cannot be used, which is the most common reason an update refuses to start.
SH-01A
Clear at 1.06 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.06 | Sound mid-set | Unintended muting could occur depending on the combination of sequencer playback, the TRANSPOSE switch and sound-production information. |
One named fault, which reads as a dead machine, not a bug: a part going silent mid-sequence, triggered by a control the performer is holding. The capability floor is 1.07 of January 2019, which added USB and MIDI as MIDI clock sources and made soft thru switchable. Below it this machine cannot take a clock over USB at all. That is the same change, in the same month, that the TR-09 and TB-03 received at their own 1.06 and the TR-08 at its 1.07: Roland version numbers do not line up across the Boutique line but the dates do. 1.08 of November 2021 changed only the version number, for management reasons. Roland's product is the SH-01A. There is no SH-1A.
SE-02
Clear at 1.11 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.11 | Playback mid-set | How parameters played back when switching patterns, and the SONG tempo setting. |
| 1.11 | Display | Incorrect appearance of the PATCH SETUP display. |
| 1.05 | Sound mid-set | Pitch could waver when the OSC3 level was raised. |
The 1.05 pitch fault is easy to miss: on an analogue synth a wavering pitch reads as character, not as a defect, and can go unrecognised indefinitely. Nothing has been published for this machine since June 2018. The 1.10 release of May 2018 was a large feature addition, including Bank D and real-time pattern recording, and is not listed as a fault.
TB-03
Three releases, and none is a fix to chase. As with the TR-09, the one that matters is 1.06 of January 2019: it added USB and MIDI as MIDI clock sources and made soft thru switchable, so below that version this machine cannot take a clock over USB. 1.04 of November 2016 added preset patterns, a pattern copy function and a random pattern generator, and those patterns need a factory reset after updating before they appear. 1.07 of November 2021 changed only the version number.
TB-3
The TB-3 has one system update, version 1.1, available as a download with an update-procedure PDF. Release notes: N/A. The SP-404A is different: Roland never published a system program for that machine at all. Confirm which machine you have: the TB-3 is the 2014 AIRA Touch Bassline, 240 mm wide with quarter-inch outputs and five-pin MIDI. The TB-03 is the 2016 Boutique reissue, 308 mm, with 3.5 mm audio and CV and GATE outputs. They have separate pages here and separate firmware records.
MC-707
Clear at 1.82 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.82 | MIDI mid-set | Playing the arpeggiator from an external MIDI keyboard could make it uncontrollable. |
| 1.82 | MIDI mid-set | When switching clips, the MSB and LSB of the Bank Select being sent were reversed. |
| 1.81 | MIDI mid-set | The arpeggio could stop working correctly when the MIDI channel was changed. |
| 1.72 | Sound mid-set | No sound when pads were routed to COMP1-6 on a DRUM + COMP track. |
Four named faults, three of them MIDI, and the fourth is silence when pads are routed to COMP1-6 on a DRUM + COMP track. All are fixed by 1.82. The MC-707 and MC-101 share one codebase: the same version numbers carry the same fixes on the same dates, and both stopped at 1.82 in June 2023, so comparing the two by version tells you nothing. The releases that changed what the machine can do are 1.80 of September 2022, which added clip save, undo and redo, and Roland Cloud pack import, and 1.71 of May 2021, which added the scene chain and delay and reverb sends on EXT IN and PC IN.
MC-101
Clear at 1.82 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.82 | MIDI mid-set | Playing the arpeggiator from an external MIDI keyboard could make it uncontrollable. |
| 1.82 | MIDI mid-set | When switching clips, the MSB and LSB of the Bank Select being sent were reversed. |
| 1.81 | MIDI mid-set | The arpeggio could stop working correctly when the MIDI channel was changed. |
| 1.81 | Browse | SDZ files could not be loaded once more than 33 SDZ or SVZ files were present. |
| 1.81 | Browse | The drum kit inside an SDZ file could not be loaded. |
| 1.72 | Sound mid-set | No sound when pads were routed to COMP1-6 on a DRUM + COMP track. |
The three MIDI faults and the COMP routing fault are the MC-707's, fixed on the same dates at the same version numbers, because the two machines share a codebase. The two SDZ loading faults at 1.81 are not on the MC-707 (the MV-1 has them too), and they bite at load time rather than during a set. Both machines stopped at 1.82 in June 2023. The capability releases are the same pair as the MC-707: 1.80 of September 2022 and 1.71 of May 2021.
MV-1
Clear at 1.82 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.82 | MIDI mid-set | Playing the arpeggiator from an external MIDI keyboard could make it uncontrollable. |
| 1.81 | MIDI mid-set | The arpeggio could stop working correctly when the MIDI channel was changed. |
| 1.81 | Browse | Wave file loading could fail on a Vocal Track. |
| 1.81 | Browse | SDZ files could not be loaded once more than 33 SDZ or SVZ files were present. |
| 1.81 | Browse | The drum kit inside an SDZ file could not be loaded. |
The MV-1 is the third machine on the MC codebase. It stopped at 1.82 in June 2023 on the same day as the MC-707 and the MC-101, its 1.81 carries the same SDZ loading faults and the same arpeggio-on-MIDI-channel-change fault, and Roland's 1.80 notes announce an import function for "MC and MV Production Packs". One fault here belongs to this machine alone and could not exist on an MC: wave file loading failing on a Vocal Track, also fixed at 1.81. The release to have for what it adds is 1.80 of September 2022, which brought undo and redo, panning for vocal takes, a fade out during mixdown, SMF import and Zenbeats integration. Updating is not done over USB on this machine: Roland require a computer with an SD card slot and a card formatted on the MV-1 itself.
SP-404MKII
Clear at 5.51 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 5.51 | Performance mid-set | The system may hang during certain operations. |
| 5.00 | Performance mid-set | The unit restarts when you perform certain operations in DJ MODE. |
| 4.07 | Browse | Importing several samples at once made them all the same sample. |
| 4.06 | Performance mid-set | A crash under certain conditions when importing samples from an SD card in DJ Mode. |
| 4.05 | Performance mid-set | A crash when sampling or resampling is performed after importing a sample. |
| 4.04 | Performance mid-set | A crash under certain conditions in DJ Mode. |
Six rows out of a longer list: Roland documents a dozen more fixes that a studio user would meet and a performer would not. Five of the six rows are the unit stopping (a hang, a restart or a crash), and three of them name DJ MODE specifically. The last release listed is 5.52 of June 2026, a version-number change made for management reasons. The releases to have for what they add are 5.00 of April 2025, which let the SP-404MKII operate Serato DJ and Serato Studio, and 5.50 of April 2026, which added side-chain compression and support for SDXC cards in exFAT format. Below 5.00 this machine does not drive Serato at all.
SP-404A
There is no firmware for the SP-404A: Roland has never published a system program for this machine, and no driver either. Its Updates & Drivers page carries exactly three things, and none of them is firmware: the SP-404SX Wave Converter for Windows and for macOS, which is software for a different machine, and the factory sample content that shipped on the included SD card. The machine is as it was the day it was built: nothing can be broken by an update and nothing can be gained from one, and there is no version to check before a gig.
VT-4
Clear at 1.03 or later
| Fixed in | Area | What was happening below that version |
|---|---|---|
| 1.03 | MIDI mid-set | With a realtime message arriving at MIDI IN, specific REVERB types failed to synchronise with the tempo. |
One named fault in the machine's history, and it is hard to attribute: it appears only when something else is driving the VT-4 over MIDI, so it looks like the sequencer's problem, not the processor's. The release that changes what the unit can do is 1.02 of November 2018, which added settings for constant pitch and formant conversion, a mute feature, and a setting that turns the robot voice OFF when MIDI note input stops, which a performer notices: without it, an interrupted MIDI stream leaves the voice stuck. The update cannot be run on batteries. Roland state the update is carried out using USB power and that the VT-4 cannot be updated on battery power, so a unit on four AA cells cannot be updated.
VP-03
Roland has published no defect for the VP-03. Two releases exist and neither is a fix: 1.06 of January 2019 is a version-number change made for production reasons with specifications unaffected, and 1.04 of November 2016 added an adjustment for the sampling threshold and a pre-sampling time setting. Both additions are for the sampling function, not the vocoder, and a unit below 1.04 cannot set either. Updating needs a micro USB data cable: Roland state that dedicated charging cables cannot be used, which is the usual reason an update refuses to start and looks like a dead port. The version check is a light pattern rather than a screen: hold button 1 while switching on, and buttons 8, 14 and 15 lit means the machine is current.
How to read this
A version in the "Fixed in" column is the release that resolved that fault. Anything below it still has the fault. Anything at or above it does not.
The mid-set marker is ours, not Roland's. It flags faults whose documented symptom can interrupt a set already in progress, so you can tell a real risk from an inconvenience at a glance. Everything else here is Roland's wording, condensed.
Version numbers do not compare between machines. The TR-8S is on 3.00 and the TR-08 on 1.08, and neither number says anything about the other. Read each machine against its own column.
Faults only. Feature additions are left out because a missing feature does not end a set. Two phrases Roland uses constantly are also left out: "minor bugs have been fixed", which says nothing a reader could recognise, and "the version number has been updated due to management-related circumstances", which is not a release. Where a machine has a clean published record, its section says so. Found something we have wrong? Tell us and we will check it against the source.
Keep the Emergency Card